In-Command®/First-In/Full-Crew

In-Command® Full-Crew and In-Command® First-In

  • (1) Emergency Signaling including MAYDAY, EVAC, PAR and ROLL-CALL
  • (2) Automated wireless Accountability of ALL Personnel
  • (3) In-Command® Full Crew, full-featured
  • (4) In-Command® First In, rapid mobile setup
(1) Emergency Signaling with immediate notification and control:
  • MAYDAY, automatically sent upon motion time-out or pressing panic-button
  • EVAC, evacuate one, a group or all Firefighters at any time
  • PAR, personnel accountability report with Firefighter acknowledgement, frees up voice radio channel and is configurable to your departments protocol
  • ROLL-CALL, for escalated emergency signaling and Accountability
(2) Automated wireless Accountability of ALL Personnel at ALL times is achieved through the Firefighter’s use of the TPASS®5 and incident command and support personnel through use of SuperCELL® SC500 or WorkForce® signaling units
  • TPASS®5 is the only NFPA compliant, stand-alone RF PASS available and has become the industry-benchmark of performance and first choice of Firefighters providing Accountability and emergency signaling including MAYDAY, EVAC, PAR and ROLL-CALL
  • SuperCELL® SC500 is the product of choice used by Incident Command, capable of monitoring all personnel safety with immediate notification of Firefighter MAYDAY and has the capability to immediately send EVAC signals to all Firefighters and personnel
  • WorkForce® models WF1 and WF2 C500 are most often used by the many support personnel present at the emergency incident providing them with safety monitoring, Accountability and emergency signaling including EVAC, PAR and ROLL-CALL
(3) In-Command® Full Crew is an advanced wireless Emergency Signaling and Automated Accountability Safety System featuring the NFPA-compliant TPASS®5 as the Firefighter’s primary RF PASS. Incident Command has full Accountability and monitoring of personnel on scene including immediate notification of Firefighter MAYDAY. Other powerful features are used to more efficiently monitor the safety of all personnel including EVAC, PAR checks and ROLL-CALL signaling. The automated PAR check feature is setup to your department’s protocol to periodically signal each Firefighter and person on-scene, prompting them for an acknowledgement. Most important, the PAR feature DOES NOT USE A VOICE RADIO and can eliminate the chaos of having to discern who has responded to PAR. In-Command® Full Crew software runs on a Windows PC or Windows tablet, identifies all personnel present by name and ID number, data-logs all signaling events and can generate a report of the incident for record keeping and future reference. In-Command® Full Crew has many other advanced features and protects ALL Firefighters at ALL times and contributes in maintaining **NFPA 1500 compliance. In-Command® Full View has advanced mapping features to locate and monitor the safety of Wildlands Firefighters and SAR teams. (4) In-Command® First In operates using Android tablet software and the Incident Command Monitor. Rapid, easy setup makes First-In ideal for departments that need immediate Firefighter protection with minimal dedicated personnel. In addition to the tablet, the Incident Command Monitor serves as a separate, independent alarm monitor providing loud sirens and strobe light warning of a Firefighter MAYDAY. In-Command® First In provides Automated Accountability and many of the emergency signaling features as Full Crew while providing mobility for the incident commander. A fast, easy 3 step solution to safely monitor your Firefighters and provide Accountability: Step 1: Place the Incident Alarm Monitor on the Fire ground Step 2: Turn the key to the ON position to power up the system Step 3: System is actively monitoring Firefighter safety in 45 seconds Launch the In-Command® First In tablet app and begin actively monitoring your Firefighters and fire ground personnel. In-Command® First In provides Automated Accountability and emergency signaling management of Firefighters with TPASS®5 and support personnel through use of SuperCELL® SC500 or WorkForce® emergency signaling units. Protect ALL Firefighters at ALL times with In-Command®.   In-Command® Emergency Signaling Automated Accountability Systems Features:
  • NFPA-Compliant, RF PASS Emergency Signaling and Automated Accountability System
  • Protects ALL Firefighters and ALL Fire ground Personnel at ALL times
  • Automated Accountability, knowing which Firefighters Fire ground personnel are present and safe
  • MAYDAY immediate notification, identifying the Firefighter by name
  • Automated PAR check, configure to your department protocol:
    • Does not use a voice radio channel
    • Set PAR time interval to your choosing, or on demand
    • Eliminate chaos caused by poor, muffled voice quality
    • No longer interrupt fire ground operations to run a PAR
    • Know which Firefighters have or have-not acknowledged PAR
  • EVAC one, many or all Firefighters at the touch of a button without using voice radio
  • ROLL-CALL signaling to step up the level of your Firefighter safety checks
  • Firefighter Acknowledgements of receiving EVAC, PAR, ROLL-CALL signals
  • Operates on an autonomous radio system totally separate from the voice radios
** “NFPA 1500 specifies the minimum requirements for an occupational safety and health program for fire departments or organizations that provide rescue, fire suppression, emergency medical services, hazardous materials mitigation, special operations, and other emergency services.” Reference: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and-standards/detail?code=1500 The table below compares the primary features and capabilities of the In-Command® Full-Crew and First-In systems.
FeatureIn-Command Full CrewIn-Command First-In (Android Tablet)
GRAPHICAL INCIDENT MONITORING • MONITOR SEVERAL HUNDRED USERS SIMULTANEOUSLY • ALARMS • BATTERY • NO SIGNAL • PAR STAGES • ROLL CALL STAGES • EVACUATION STAGES • DEVICE TYPE • ONLINE TIME • ONLINE COUNTYESYES
INCIDENT START / STOPYESYES
INCIDENT AUTO SAVEYESYES
WIRELESS CONNECTIVITY (WIFI)NOYES
CONNECTION KEEP ALIVEYESYES
USER GROUPINGYESNO
PRIORITIZED DISPLAYYESYES
CONFIGURABLE DISPLAY PRIORITY TYPEYESNO
MONITOR ALARM CONDITIONS • MOTION ALARM • PANIC ALARM • HEAT ALARM • LOSS OF SIGNAL ALARMYESYES
POPUP ON ALARMYESYES
PLAY AUDIO ON ALARM AND EVACUATIONYESYES
MONITOR NO SIGNAL CONDITIONSYESYES
MONITOR LOW BATTERYYESYES
PERFORM EVACUATIONSYESYES
PERFORM PARYESYES
PERFORM AUTO PARYESNO
INCIDENT EVENT LOGGINGYESYES
INCIDENT RADIO TRAFFIC LOGGINGYESYES
INCIDENT STATISTICSYESNO
EVENT NOTIFICATIONS (EMAIL, SMS, CANNED MESSAGE)YESNO
CANNED MESSAGE TX AND RXYESNO
USER LOCATING USING GRACE LOCATORSYESNO
RECEIVER BATTERY MONITORINGYESYES
INTERNET CONNECTION DETECTIONYESYES
INCIDENT CONFIGURATION • CONNECTION SETUP • NAME FILE CREATION • CHECK FOR NO SIGNAL • NO SIGNAL TIME • NO SIGNAL CAUSES ALARM • REAL TIME CLOCK MESSAGE • AUTO SAVE TIMEYESYES
EXTENDED INCIDENT CONFIGURATION • MULTIPLE CONNECTIONS • CONFIGURATION PASSWORD PROTECTION • 10 AND AUXILIARY ID’s • TYPES • PLANS • POSITIONS • COMMANDERS • SHIFTS • RUN CARDS • RANKS • SECTOR • RESOURCE • CUSTOM AUDIO SOUNDS • CUSTOM COMPANY LOGO • NOTIFICATION SETUPYESNO
CREATE NAME FILES • ASSIGN ID’s • SET NAME • ASSIGN DEVICE TYPEYESYES
CREATE EXTENDED NAME FILES • USER PERSONAL INFORMATION • USER IMAGE • LEGACY SUPPORT • USER NOTESYESNO
INCIDENT LOCATION SETUP • INCIDENT 10 • INCIDENT LOCATION ADDRESS • INCIDENT DETAILSYESYES
EXTENDED LOCATION SETUP • PRE CONFIGURE LOCATIONS • LOCATOR BEACON MAPPING • LOCATOR GPS ASSIGNMENT • LOCATOR BEACON BATTERY MONITORINGYESNO
CONFIGURATION BACKUP AND RESTOREYESNO
In-Command® Full-Crew and First-In Chart (PDF) In-Command® Full-Crew software operates on a Windows PC. In-Command® First-In software operates using a (Android) Tablet and connects to the Incident Alarm Monitor via a WiFi link. Please consult with our experienced sales professionals to discuss which option will best suit your needs. Product Literature Request a Quote Accessories